dr_coffee
Joined 10 years ago
Joined 10 years ago
I am sure this is not the first time conductive AFM has been used to achieve nanoscale patterning to build a useful piece of tech, but very cool nonetheless.
A similar optical pickup made of optical components from newport or thorlabs would run you a few thousand dollars, whereas these dvd optical pickups can be had for $10-20.
Here is another great paper (and accompanying youtube video) that shows optical trapping, atomic force microscopy, and even imaging with a dvd optical pickup.
https://siril.readthedocs.io/en/stable/processing/deconvolut...
this paper came out a few years ago using super resolution fluorescence and dna origami to track unwinding of dna by single helicase enzymes! its not an easy technique but it is doable with the right equipment (the 2014 Nobel Prize in chemistry was for super resolution microscopy)
VV ECMO, on the other hand, is used purely for gas exchange (O2 and CO2) due to respiratory failure. Much of the debate in the critical care community is centered around which circumstances and patients derive the most benefit from initiation of VV ECMO. The best studied use case, is in the setting of acute respiratory distress syndrome, which is defined by very specific criteria (bilateral noncardiogenic pulmonary edema with ratio of arterial oxygenation partial pressure to fraction of inspired oxygen less than 300 mmHg). The EOLIA trial published in NEJM in 2018 looked at early initiation of VV ECMO in patients with severe ARDS [1]. It demonstrated no mortality benefit of ECMO, however many say that the study was not appropriately powered as the assumptions used to design the study were from 2008 when mortality from ARDS was much higher. Re-analysis of the data from the EOLIA trial using bayesian methods suggests that there might actually some benefit to early initiation of ECMO [2]
1. https://www.wikijournalclub.org/wiki/EOLIA
2. https://jamanetwork.com/journals/jama/fullarticle/2709620
https://hackaday.io/project/9205-blubeam-a-scanning-laser-mi...
https://hackaday.com/2019/11/12/tearing-down-a-ps3-blu-ray-d...
Heres a decent open source? stage that i adapted for one of my projects in the past. Resolution is 1 micron laterally. If i remember correctly they address several issues including stepper motor backlash and micro-stepping. Cost can be well below the $1000 they quote depending on the parts you choose, or e.g. if you do only two axis (xy) stage instead of three (xyz)
Otherwise it really is a pleasure to use, and I have found that the LTS install has zero compatibility issues thus far.
https://www.reuters.com/world/asia-pacific/bessents-to-do-li...