negative_zero
Joined 8 years ago
Joined 8 years ago
I hope it's at least "probably fine". I've seen some pretty shoddy electrical work in my lifetime (including new installs) and am now of the mind that the deep-defense-in-depth of electrical safety we have these days is to also "cope" with shitty electrician work.
Not picking on the US though. These panels in their current incarnation, are lowering the level of safety of electrical everywhere.
This is all just my opinion though. A lot of my background is in compliance. I've been frustrated by some obvious electrical safety advancements that are STILL not being implemented. I also have first hand experience with many many signed off electrical systems which were death traps. This all biases me heavily towards not compromising on electrical safety. But maybe I am overreacting.
To use your car analogy, we're not banning vehicles. We're disable one of the airbags when enabling fuel economy mode.
Don't get me wrong, I think they're a spectacular idea, especially for renters. But you'd need an electrician to check the circuit and maybe even have a special balcony-solar-plug to prevent people plugging in too many panels in the wrong locations.
Quick edit: Random idea. I guess if the panel could communicate with the RCBO it's connected to and that RCBO can dynamically alter it's trip current could also solve it. But again, that's an electrician call and new thing installed.
i.e You have a circuit with max current 16A; clever end-user plugs in 3 x 800W panels into different sockets BUT they are unfortunately on the same circuit; now 26A can be potentially drawn through a single cable IN THE WALL without tripping the breaker. This is a BIG fire hazard.
And you can't wave this away with instructions. It has to be 100% impossible for an end-user to do this.
https://youtube.com/watch?v=bNN9XhGZ3Yw
(Also The Centre for Computing History YouTube channel is seriously underrated)
"ERCOT said it is reviewing the test failures and drawing up plans to protect the grid from disruptions."
Why are they even allowed to connect? / Why are they not kicked off? / Why aren't they being forced to add their own grid inertia?
I personally really dislike the screen ones. They're slower, less reliable and the location is unnatural.
If something like Nepenthes added poisoned pages to it's tarpit then a small number of users can just poison all LLMs?
I've worked in payment terminal hardware security and this is not surprising to me at all.
This attack on the Ledger wallets would definitely rate as amateur in terms of sophistication in that world.