Those with older PSUs should have had to make a decision about whether they want an adapter or not, and then pick an adapter of the appropiate quality.
I think it would have been better for these cards to not have an adapter at all. I've added an EDIT to try to word this differently.
Those refer to a PCI Express Forum issue that was opened about the connector drawing too much power, not the adapter.
I'd recommend people gloating to read the article. EDIT: (see my edit below).
The conclussions are clear:
- The problem is NOT the new connection; that's fine. New PSUs come with a connection that does not need any adaptor and those are safe and work fine.
- The problem is a poor quality adaptor shipped with 4090s for people that buy a 1600$ GFX but then skimp on a new PSU and want to pair it with an old one (EDIT: skimp is out of place and victim blaming, I'd guess it would be more appropiate to have said here that NVIDIA and partners decided to add an adapter to avoid suggesting that users need a new PSU).
These adaptors are distributed by NVIDIA but build by a supplier. Igor's recommendation is, I quote: "NVIDIA has to take its own supplier to task here, and replacing the adapters in circulation would actually be the least they could do.".
EDIT: This comment can be misunderstood as me speculating whether the OP read the article or not. I am not speculating: the OP did not read the article, which claims the opposite of what the OP claims. The OP claims that 12V solutions are the issue, while the article states that they are fine, and as proof shows that new PSUs implement them correctly. In fact the _goal_ of the article is to set the record straight about this, by precising that the only problem is the quality of the adapter, not 12 V per se. So this comment is not an speculation about whether the OP read the article or not, but a response to set the record straight for those who might read OPs comment only, but not the article (I often come to HN for the comments more than the articles, so I'd find such a comment helpful myself).
Cars stop on the left, which allow other cars to overtake them on the right.
This surprised me when visiting the UK.
I actually expected people to stand on the "left" of the scalators - just like how they drive on the left and overtake on the right - but they didn't. They stood on the right.
I was left puzzled ???
In the Grace Hopper whitepaper, NVIDIA says that they connect multiple nodes with a fabric that allows them to creat a virtual address space across all of them.
Every build system that has added support for Rust, which aren't many, had to be radically modified to achieve that.
None of these supports the GCC Rust frontend, but all of them support the Rust frontend.
So if you actually wanted to build any >100 LOC Rust project for embedded targets not supported by LLVM, doing it with the Rust frontend is as easy as just running 1 CLI command to pick its GCC backend.
Doing it with the GCC frontend, would require you to either port one of the build systems to support it, or... give the GCC frontend a CLI API that's 100% compatible with the Rust frontend.
This post is about a new front-end.
The hardware can back up the 1024-bit register with a pool of 32-bit registers, and if you only wrote to the first 32-bits, and all others are zero, it can use a single 32-bit register to back it up, making this "as good" as the single mask register solution, which the author thinks is good.
I use nvidia containers on HPC systems every day and accessing NICs, doing RDMA to GPUs, etc. "just works" and performs as well as baremetal. Every time we upgrade our container we verify the new container with a set of benchmarks against both the old one and baremetal.
> You don’t want to give indirect root access via docker group, too.
I don't know of any HPC center using docker though. It does not sound like a good idea because the docker daemon runs as root..