One of our vendors is a contract electronic manufacturer (circuit board stuffer) that has a wave soldering machine running MS-DOS on a PC that's built into the control cabinet. It uses the parallel port to communicate with Opto22 industrial i/o modules, which then is wired to all the temp sensors, relays, etc. It just keeps working.