Comment by formerly_proven

> The input to the ADC is clearly already chopped into discrete samples, with a new sample every 120 ns. We can discern a sine wave in the samples, but there’s a lot of noise on the signal too. Meanwhile the TDS684B CRT shows a nice and clean 1 MHz signal. I haven’t been able to figure out how that’s possible.

Is this maybe using some form of correlated double sampling?

> It looks like the signal doesn’t scan out of the CCD memory in the order it was received, hence the signal discontinuity in the middle.

Or maybe the samples are also interleaved in the low-order bits in some way. This could be because the organization of the CCD isn't symmetric for the input and output paths, perhaps to reduce area or power, since only one path has to be fast. This would make sense because if you implement the CCD using n parallel CCD bucket brigades you only have to put a fast S&H and multiplexer in front of it, then you can drive the CCD brigades at a fraction of the actual sample rate, and the capacitive load of each of those clock phases is much lower as well.