Comment

Comment by jacquesm

Such a soft failure would be concerning. One BMS that I am intimately familiar with has two thermistors, one stuck to the batteries using a plug and a short cable, another surface mounted on the BMS board, if the delta between the two gets too large it shuts down any charge cycle in progress and bricks itself. Pretty harsh but given the alternatives it is the only safe thing to do.
parent jacquesm 4 years ago