Comment Comment by ora600 required.acks works together with min.insync.replicas.Basically "required.acks" lets you choose between "no acks", "leader only" and "all in sync replicas", while min.insync.replicas lets you control what "all in sync replicas" actually mean. parent ora600 10 years ago
Basically "required.acks" lets you choose between "no acks", "leader only" and "all in sync replicas", while min.insync.replicas lets you control what "all in sync replicas" actually mean.